WLL MECHANICAL SPLICE FIBER CORE Next: (continued)  
SLINGS
WIRE ROPE
WORKING LOAD LIMITS
MECHANICAL SPLICE
FIBER CORE
1 PART SLINGS
3
4 LEG BRIDLE
RATED CAPACITY IN TONS OF 2,000 LBS.
RATED CAPACITIES SHOWN APPLY ONLY TO 6X19 AND 6X37 CLASSIFICATION WIRE ROPE.
VERTICAL
60 DEGREES
45 DEGREES
30 DEGREES
ROPE 
DIA. (IN)
EIPS
EIPS 
EIPS
EIPS
1/4
2.2
1.9
1.6
1.1
5/16
3.5
3.0
2.5
1.7
3/8
5.0
4.3
3.5
2.5
7/16
6.7
5.8
4.8
3.4
1/2
8.7
7.5
6.2
4.4
9/16
11
9.5
7.8
5.5
5/8
14
12
9.6
6.8
3/4
19
17
14
9.7
7/8
26
23
19
13
1
33
29
23
17
1 1/8
42
36
29
21
1 1/4
51
44
36
26
1 3/8
62
53
44
31
1 1/2
73
63
52
36
1 5/8
85
73
60
42
1 3/4
98
85
69
49
1 7/8
112
97
79
56
2
127
110
90
63
RATED CAPACITIES BASKET HITCH BASED ON D/d RATIO OF 25.
RATED CAPACITIES BASED ON PIN DIAMETER NO LARGER THAT NATURAL EYE WIDTH OR LESS THAN THE NOMINAL SLING DIAMETER.
RATED CAPACITIES BASED ON DESIGN FACTOR OF 5.
HORIZONTAL SLING ANGLES LESS THAN 30 DEGREES SHALL NOT BE USED.
57